9040: Bleeder temperature model: Overtemperature - Movement stopped

Info: Temperature limit
Data type: REAL

Description:
Runtime error if the temperature of the braking resistor temperature model TEMP_BLEEDER exceeds the limit (see INFO) (external -> TEMP_MAX_BLEEDER_EXT | internal -> see following list).

The limit of the internal braking resistor is dependent on the ACOPOS servo drive:
8V1010.xx-x....250°C
8V1016.xx-x....250°C
8V1022.xx-x....400°C
8V1045.xx-x....400°C
8V1090.xx-x....400°C
8V1180.xx-x....350°C
8V1320.xx-x....350°C
8V1640.xx-x....400°C
8V128M.xx-x....400°C

Reaction:
See error number 9000.

Cause/Remedy:
Recovery power increased:
-> Check the dimensioning of the braking resistor (see user's manual). The braking power is distributed on the controllers which are switched on if DC bus's from multiple ACOPOS servo drives are linked together.

Heat sink temperature sensor: See error number 9000.

ACOPOS servo drive defect:
- DC bus voltage measurement problem: -> Check the DC bus voltage UDC_ACT with a multimeter.